The wet bar and/or the cabin can be equipped with an LPG-fueled gas cooker. The cooker comes with LPG hoses and a valve.
Quarken does not provide the LPG cylinder, pressure regulator and pressure gauge, which are needed for the system to be fully functional.
-
Gas cooker (on the wet bar)*
-
Storage for LPG cylinder
*Optional
An open-flame appliance always poses a risk of fire.
-
Never leave the cooker unattended when in use.
-
Never smoke or have an open flame when the appliance is in use and when replacing the cylinder.
In a confined space there is a risk of carbon-monoxide poisoning as the gas cooker consumes cabin oxygen and releases combustion substances.
-
Ensure proper ventilation in the cabin when the appliance is in use. Open ventilation openings. Never obstruct them.
-
The ventilation has been designed for LPG appliances as installed. Additional ventilation may be required if you use other appliances simultaneously.
-
Do not use the cooker for heating confined spaces.
Leaks contain a risk of fire and carbon-monoxide poisoning.
-
In case of a leak, immediately shut off the main LPG supply valve and discontinue using the cooker.
-
Never use a flame to check for leaks.
-
Do not use solutions containing ammonia for manual leak testing.
-
Do not use an installation that has leaked until it has been inspected and repaired by a competent person.
Before using the cooker, make sure that:
-
The cylinder is properly hooked onto the hose.
-
The conditions are stable with no high angles of heel to be expected.
It is recommended that you use a gas detector alarm.
Follow the cooker manufacturer’s recommendations on the maximum operating pressure of the cylinder.
For detailed instructions for use, see the manufacturer's manual.
Always keep the LPG cylinders, pressure regulator and pressure gauge in the dedicated LPG locker.
Always make sure that the LPG supply line valves and cylinder valves are closed:
-
When the cooker is not in use
-
Before replacing a cylinder
-
Immediately in an emergency.
Keep empty and reserve cylinders closed and disconnected. Always store them in the dedicated LPG cylinder lockers.
Do not use the LPG cylinder lockers for storage of any other equipment.
Do not modify the craft’s LPG system yourself. Installation, alterations and maintenance must be performed by a competent person.
Have the system inspected at regular intervals or as required by national requirements.